How much should the thickness of the foundation slab be and how to calculate the indicator correctly?

One of the most crucial things to get right when building a house is the foundation. The foundation slab ensures stability and durability by offering the essential support for the entire structure. So what should the thickness of this slab be? Every builder or homeowner will encounter this typical query during the planning phases of construction.

The foundation slab’s thickness isn’t a universally applicable number. It depends on a number of things, such as the kind of soil, the weight that the slab must bear, and the building’s actual design. It is crucial to take this measurement accurately since a poor foundation can eventually cause major structural problems. Conversely, an overly thick slab may result in material waste and increased expenses.

A combination of local building codes and science are used to calculate the proper thickness. Typically, a residential building’s slab thickness falls between 4 and 6 inches. However, depending on the particulars of your build site, this may change. By being aware of these factors, you can choose the right thickness for your foundation slab, giving your house a sturdy and long-lasting foundation.

This post will examine the main variables that affect foundation slab thickness and offer a detailed explanation on how to determine the appropriate thickness for your project. By the time you’re done, you’ll know exactly what factors go into making this important choice, which will help you lay a solid and secure foundation for your new house.

Question Answer
How much should the thickness of the foundation slab be? The thickness of the foundation slab typically ranges from 4 to 12 inches (10 to 30 cm) depending on the type of building, soil conditions, and load requirements.
How to calculate the thickness correctly? To calculate the thickness, you need to consider factors like soil type, load from the structure, and local building codes. Consult with a structural engineer for precise calculations tailored to your specific project.

What does the indicator depend on??

Here, the slab serves as the entire structure’s monolithic reinforced base.

The following layers make up the power structure and are fundamentally important:

  1. compacted cushion made of non-metallic materials;
  2. heat insulator and waterproofing;
  3. footings, as well as directly concrete slab with embedded reinforcement frame.

The strength and dependability of the base are determined by the thickness of the monolith, which is dependent on several factors, such as:

  • characteristics of the soil under the supporting base area;
  • laying depths of the power structure;
  • design loads, which are determined by the design features of the structure, operating conditions, and climatic conditions in the region.

Expert designers consider each of the aforementioned aspects, which necessitates in-depth knowledge of the technology and slab structure laying experience.

Private developers employ a streamlined process that is predicated on considering three factors in order to avoid hiring experts:

  • reinforcement thickness;
  • gap between reinforcing chords;
  • thickness of concrete above and below the reinforcement cage.

The three given parameters add up to a slab thickness that typically ranges from 0.2 to 0.3 m. The final indicator is modified in light of the future building’s complex design, the uniformity of the rock occurrence, and the properties of the soil.

Apart from the evaluation provided by experienced builders, it is mandatory to verify the chosen slab thickness in connection to the parameter – the ideal specific pressure of the structure on the ground – as per the established standards (further information is provided in the table).

It is deemed that the slab thickness was appropriately selected if the pressure the building will apply to the ground in accordance with the project deviates from the reference value by no more than 25% either way.

Optimal value of distributed load (kgf/cm²) depending on soil type
plastic clays, sandy loams 0.50
dense sands, loams 0.35
medium density sands, hard clay 0.25

Minimum figures according to SNIP, SP

The current standards (SNiP 2.02.01-83 and SP 50-101-2004) state that the minimum height of the foundation structure, including all layers, must not be less than 0.6 m.The plate itself must have a minimum thickness of 0.10–0.15 m.

If the concrete of a brand is not chopped to at least M300 with a strength of B22.5, the smallest value of the parameter may be used, provided that it complies with the Rules of SNiP and SP.

The developer must reinforce the plate to guarantee the required reserve of strength, which will eventually enable the foundation to be resistant to soil deformation.

Selecting an excessively thick plate will result in more than just excessive material and labor costs. A monolithic foundation and significant pressure from the house will eventually cause the structure to sink into the earth.

Overly "light" pressure will therefore cause the plate to move in response to even the smallest changes in the soil (such as when the earth thaws in the spring), which will lower the extension’s overall operational resource.

Taking into account the type of soil, total loads, and other factors, the designer’s tasks entail determining the minimum permissible slab thickness.

Average indicators for different buildings

A monolithic base slab’s thickness has a very narrow range of acceptable values. When building private homes, you should pay attention to the following signs:

Type of construction Slab thickness, m
Lightweight buildings, garden structures 0.10–0.15
Brick toilets, garages, bathhouses 0.15–0.20
One-story frame, wooden or foam concrete house 0.20–0.25
One-story house made of brick or concrete 0.25–0.30
Two-storey house 0.30–0.35
A brick house or a building made of other heavy building materials with several floors 0.30–0.40

You can assess how the thickness of the slab relates to the weight and complexity of the structure being constructed using the values in the table. Raising the thickness to 0.5 m is not recommended because the structure will no longer be able to move with seasonal soil movements, which is the primary benefit of the "floating" slab. Precise indications are acquired through computation during the slab base design phase.

How to calculate?

The simplest method for determining a slab base’s thickness is to add up three factors:

  • the gap between the reinforcing belts;
  • rod thickness;
  • thickness of the protective concrete layer around the frame (from 4 cm)

The pertinent paragraphs in SNiP 52-01-2003 and SP 52-103-2007 govern the guidelines for reinforcing reinforced concrete foundations.

Calculations based on the loads from the future structure are more reasonable. For instance, a slab of 0.1 m in height will do for a light agricultural building and 0.2–0.3 m for a country house.

In this instance, consideration of the structure’s characteristics is required. A house with a long and narrow foundation and few internal partitions, for instance, is more likely to experience bending loads, which could cause the foundation slab to crack roughly in the middle. The monolith’s thickness is intentionally increased to prevent this.

Initial data for calculation

Therefore, the following details are necessary for the developer to ascertain the slab’s thickness:

  • know the type of soil and, as a result, the optimal value of the distributed load;
  • know the structural parameters of the future structure and the types of materials involved in order to calculate the design loads;
  • choose the optimal reinforcement scheme for the given conditions, namely: rod diameter, mesh size, distance between chords, etc.P.

Sequence of calculations

The algorithm used to calculate slab thickness is as follows:

  1. Determination of total loads.
  2. Calculation of specific ground pressure by dividing the total pressure by the base area. The size of the slab must exceed the dimensions of the structure itself by at least 10 cm on each side.
  3. Comparison of specific ground pressure with the optimal table value.
  4. The resulting difference as a result of calculations from n.3 compensated by the mass of the reinforced concrete foundation slab.
  5. Knowing the mass of the monolith and the density of reinforced concrete, determine the volume of the structure.
  6. Find the desired height of the slab by dividing the volume by the area of ​​the base.

Analysis of results

The outcome is deemed ideal if the slab height, as determined by the previously mentioned algorithm, falls between 0.2 and 0.35 meters. Generally, the value is rounded to the nearest multiple of 50, either up or down. The load is then recalculated for reliability and compared to the suggested reference value, with a maximum difference of 25%.

If the height of the slab exceeds 0.35 meters, the developer has good reason to believe that, given the circumstances, a strip or columnar foundation would be a more sensible option, as the slab is not the most economically feasible solution.

By creating stiffeners that will stop an excessively light foundation from moving horizontally, the thickness of the monolith can be decreased. In this instance, calculations are necessary and can only be completed by highly skilled experts.

It is likely that the design structure is too massive for a slab foundation if the slab thickness is less than 0.1–0.15 m. Therefore, experienced specialists should be invited to participate in the soil study and design of the load-bearing structure.

Calculation example

Given the circumstances:

  • 2-story house with an area of ​​6 by 9 m;
  • walls made of aerated concrete blocks;
  • load-bearing partition – one;
  • wall thickness – 0.3 m;
  • structure height – 5.5 m;
  • gable height – 1.0 m;
  • roof – roofing tiles;
  • bearing layer – clay (reference specific pressure – 0.25 kg/cm2).

First, the structure’s total weight is determined, which is as follows:

  • the total area of ​​all walls (with pediments and partitions, but without window and door openings) is 182 m², and their total mass is 182 × 180 = 32,760 kg;
  • monolithic floor area excluding staircase opening ~ 50 m². Then the total mass will be 50 × (500 + 210) = 35,500 kg;
  • the attic floor area is 54 m2, then the mass is 54 × (150 + 105) = 13,770 kg;
  • operational load of the 1st floor – 54 × 210 = 11,340 kg;
  • roof area – 71 m2, then the mass together with the weight of the snow layer is 71 × (30 + 100) 9,230 kg;
  • total mass of the structure obtained by summing up the results of previous calculations (102,600 kg).

The dimensions and specific gravity of the building materials used are used to calculate weights (reference information).

Next, calculate the monolith’s area (54 m2) using the project parameters, then divide the house’s total weight by that amount.

For soil, a specific pressure of 0.06 kg/cm2 short is advised. Multiply the result by the area of the base, which is expressed in square centimeters, to determine the mass of the slab:

By dividing the mass by the reinforced concrete density, you can determine the slab’s volume:

The necessary height can be calculated by dividing the volume by the base’s area:

When the slab is 0.2 or 0.25 meters high, two options can be taken into consideration under the specified circumstances. With its mass of 27,000 kg in the first scenario, the building and the foundation will exert pressure equal to:

The variation from the suggested value will be:

The slab height of 0.2 meters is chosen because the final result permits saving on concrete and satisfies the design requirements.

For any building to be stable and long-lasting, the foundation slab’s proper thickness must be determined. The type of soil, the need for load bearing, and the particular design of the structure should all be taken into consideration when determining the thickness. Although there are broad guidelines, every project may have particular requirements that must be met with careful thought and professional guidance.

Assessing the soil conditions is the first step towards accurately calculating the thickness. Tests on the soil will indicate its bearing capacity and assist in locating any possible problems, such as shifting soil or fluctuating water tables. Determining the base thickness necessary to securely support the structure requires knowledge of this information.

Next, think about the weight that the foundation must support. This covers the weight of the structure itself, the items within, and external loads like wind and snow. These data points are used by structural engineers to determine the minimum slab thickness needed to distribute the load evenly and avoid shifting or cracking.

Keep in mind that standards and building codes exist to direct these choices and guarantee security. For precise calculations suited to your particular project, you can use reputable construction software or consult with a structural engineer. Your building will be supported for many years to come by a strong, long-lasting foundation, so investing time and money in this phase will pay off.

What factor is most important for you when choosing materials for building a house??
Share to friends
Fedor Pavlov

Interior designer, author of books on residential design. I will help you make your home not only functional, but also beautiful.

Rate author
StroyArsenal62.com
Add a comment